OTDR testing and making the passport lines.
OTDR testing and making the passport lines.
Price welding optics.
We work with both cash and non-cash type payments.
We also have a license for the product of the construction work.
To order, please call from 9.00 to 20.00: 8 (727) 328 30 90 , info@s-sk.kz
Always available are crosses, couplings, cable. Also-hour emergency phone 8 (727) 328 30 90
For all questions, please call: 8 (727) 328 30 90 , info@s-sk.kz
8 (727) 328 30 90 or by e-mail: info@s-sk.kz
If necessary, can be operated at any time by appointment.
Fiber optic cables - the basis of modern data networks. Optical fiber - is the predominant media type for mission-critical data center lines, this support network within buildings, and at longer distances for campus networks. C increasing requirements for network speed and bandwidth limitations decreased distances and data loss, making testing a fiber optic cable is more important than ever. Testing of the optics is required the final stage of construction of the optical network . Optical network after installation may show through the source of visible light, but it does not mean passive optical network can provide high bandwidth.
For many decades, the optical switching equipment checked and cleaned, in order to properly pass information light beam. Although verification procedure fiber network and cleaning fiber optic connectors have long been used, they acquire a particular importance in recent years, since an increase in the data rate reduces the loss compensation budgets. By decreasing tolerances on the total loss of the light signal in the optical fiber, the attenuation level in the optical connections in the switching equipment has increasingly decrease. This is achieved through preventive measures: inspection and cleaning.
Losses in the output light pulse with the end face of the optical cable is terminated with the plug and its admission to the input adapter passage caused by two types of problems: pollution and damage.
Pollution get on the end surface of the optical cable terminated with plugs in different forms: dust, fumes, grease the touch. Usually, in simple contact with the connector end surface of human skin is delayed unacceptable amount of fat for a normal transmission optical signal. Dust and fine electrified particles are spread in the air and may be deposited on the exposed surface of the optical plug and the optical adapter. This is mainly in cross-connecting equipment, which is located at the installation stage of reconstruction, repair. When installing new hardware dust and hydrophobic gel that fills the cable can easily get to the end face of the optical plugs with protective caps.
Damage to the fiber-optic cables appears as a scratch, dent, crack or spall. These defects of the end surface of the cable may be the result of poor sealing of cable or contamination. The decision at first sopryach all connectors, and then examine only those who have not passed the test - a dangerous approach, because physical contact contamination coupled connectors can lead to permanent damage to the cable. Such permanent damage will necessitate costly and requires extra time to re-seal a cable or replace the pre-terminated lines.