Paper for an ECG of devices developing "accordion".
Carrying out diagnostics of cardiovascular system requires not only the corresponding medical equipment - the electrocardiograph, but also qualitative note paper of cardiograms. This expendable material is steadily used already many decades for registration of indications of cordial activity of the patient. Paper for an ECG differs in the high density and convenience in use.
Different devices ECG use the following options of paper: rolled, developing ("accordion") and disk. The main characteristics of paper – its length, width and density (thickness). For example, the average thickness of disk paper – 300 mm, rolled – about 250 mm.
Depending on drawing a tag and availability of perforation emit paper:
- without drawing a chart grid;
- with a tag from a grid or a thermosensitive layer;
- with a tag from a reverse side of a grid or a thermosensitive layer;
- with a tag from two parties;
- with perforation;
- with double perforation.
The printers which are built in devices ECG can carry out the ink and thermal press. The last – record on a thermal paper – is used in the most modern models of cardiographs. The thermal paper consists of several layers, has high quality of the press and protection of the image. In thermal printers are not used blackened, cartridges, a source of color is paper. But it is important to remember that such paper by definition is influenced by differences of temperatures, and it is recommended to store it at the room temperature to 30 degrees. Besides, the thermal paper differs in higher cost in comparison with the analog intended for the ink press.
Correctly to choose paper for the electrocardiograph, it is necessary to study the registration certificate of the device and the characteristic of an expendable material specified by the producer on packaging.
Technical characteristics:
Size | Description | |
50 x 100 x 300 (FQS 50-3-100) | Nihon Kohden defibrillators Cardiolife NK 201/C ECG, TEC 7100/7200/7721K |
|
80 x 70 x 315 M (with a tag) plotn. 55 g/m2 | Schiller Cardiovit AT-101 | |
80 x 70 x 315 M (with a tag) plotn. 70 g/m2 | ||
80 x 90 x 250 M (with a tag) plotn. 70 g/m2 | Electrocardiographs of the 3rd kanaln. MAC 400, MAC 600 | |
80 x 90 x 280 M (with a tag) plotn. 70 g/m2 | MAC electrocardiograph of the 400, 3 channel | |
90 x 90 x 200 M (with a tag) plotn. 70 g/m2 | Bi-phase defibrillator of ZOLL firm Models – M Series, E Series |
|
90 x 90 x 266 M | Schiller Cardiovit AT-104 PS, 3 channel ECG | |
90 x 90 x 400 M (with a tag) | Schiller Cardiovit AT-1 (the 3rd channel) | |
110 x 100 x 200 M (with a tag) | Bioset 3600/3601/3700 | |
110 x 140 x 142 Ch M (pure with a tag) (FQW 110-2-140) | Nihon Kohden, Cardiofax GEM (6 channel) ECG - 9010K, ECG - 9020K, ECG - 9022K, ECG-1250 |
|
110 x 140 x 142 M the OP222TE code (with a tag) | Fukuda Denshi CardioMax FX-7202 | |
110 x 140 x 144 M (with a tag) | Dixion ECG-1006 | |
110 x 140 x 200 M (with a tag) plotn. 70 g/m2 | The MAC 800, 6 electrocardiograph is channel | |
112 x 100 x 150 | Fetalis KMP-FM-01, KMP-FM-02 monitor | |
112 x 120 x 250 (grid of blue color) | Fetalis BFM-800 monitor BIONICS Co. LTD. (BIOSYS), Yu.Korey |
|
120 x 120 x 250 (grid of blue color) | Monitor of function of a fruit IFM-500 (BIOSYS), Yu.Korey | |
130 x 120 x 250 | Fetalis prenatal embryonal monitor "BT-300D", Bistos Co., Ltd – Yu. Korea |
|
143 x 150 x 300 Ch M (pure, two tags) | Fetalis monitor "Sonicaid Team Duo" | |
150 x 100 x 150 M (with a tag) | Avalon FM 30 (Philips) – the fetalis monitor Hewlett Packard (Philips) M 1911, M 1351FM |
|
152 x 90 x 150 code 4305 BAO.DAO | Fetalis monitor "COROMETRICS 170" ("KOROMETRIKS 170") |
|
152 x 90 x 160 code of paper 4305 AAO | Fetalis monitors: "COROMETRICS 170" ("KOROMETRIKS 170") "Overtone 6200" ("Overton 6200") |
|
210 x 140 x 156 M (with a tag) plotn. 70 g/m2 | ECG of Schiller CardioLaptop AT-110, 12 channel Schiller Cardiovit AT-10 plus, 12 channel |
|
210 x 140 x 200 M (with a tag) | Fukuda Denshi FX 4010 | |
210 x 140 x 250 M (with a tag) | Schiller Cardiovit AT-10, 6 channel | |
210 x 140 x 200 Ch M (pure with a tag) (FQW 210-3-140 code) | Nihon Kohden Cardiofax Q ECG 9110K/9130K/9132K (12 channel) Cardiofax M ECG 1350 (12 channel) |
|
210 x 150 x 200 M (with a tag) | Cardiette ar 2100 view | |
210 x 150 x 200 WC (pure, with a tag) | Nihon Kohden ECG 1550Cardiofax V (12-15 kanaln.) | |
210 x 280 x 180 M (with a tag) plotn. 55 g/m2 | Schiller Cardiovit AT-102 (6/12 channel) | |
210 x 280 x 180 M (with a tag) plotn. 70 g/m2 | ||
210 x 280 x 215 M (with a tag) | Schiller Cardiovit AT-2/AT-2plus, Cardiovit CS-200 | |
210 x 280 x 250 M (with a tag) | BTL-08 LT Plus ECG, BTL-08 LC Plus ECG (12-kanaln.) |
|
210 x 280 x 300 About (with an oval opening) density is 70 g/m2 | MAS-5000, 12-15 channel ECG | |
210 x 295 x 250 WC (pure with a tag) (FQW 210-10-295) | Nihon Kohden, (12 canal) Cardiofax V ECG 9320K |
|
210 x 300 x 150 M (with a tag) plotn. 70 g/m2 | MAC 1200, 6/12 - channel | |
210 x 295 x 150 M (with a tag) plotn. 70 g/m2 | MAC 1200 ST, 6/12 – channel (Hellige Cardiosmart) |
|
210 x 300 x 200 (two square openings), Italy | Siemens MEG Burdick E-350 | |
210 x 300 x 200 (with ovaln. opening, 1/3 leaves pure), Italy | HEWLETT PACKARD (PHILIPS) M1709A, M1700, M1701A, M2481A, M2483A, M3708A |
|
215 x 280 x 200 M (with a tag) plotn. 70 g/m2 | YM812i Mediana ECG, 12 channel | |